Real-Time MRI Analysis powered by Supercomputers

Spread the love
Raw image data collected from dGEMRIC MRI protocol at an inversion time of 1600 milliseconds (left). The T1 map computed from seven different inversion times using the automated, real-time, quantitative magnetic resonance imaging pipeline (right). Credit: Image courtesy of University of Texas at Austin, Texas Advanced Computing Center

Raw image data collected from dGEMRIC MRI protocol at an inversion time of 1600 milliseconds (left). The T1 map computed from seven different inversion times using the automated, real-time, quantitative magnetic resonance imaging pipeline (right). Credit: Image courtesy of University of Texas at Austin, Texas Advanced Computing Center

A new, automated platform that returns in-depth analyses of MRI scans in minutes, rather than hours or days has been developed by Texas Advanced Computing Center (TACC), University of Texas Health Science Center (UTHSC) and Philips Healthcare. The system has the potential to minimize patient callbacks, save millions annually, and advance precision medicine.

The team presented a proof-of-concept demonstration of the platform at the International Conference on Biomedical and Health Informatics this week in Orlando, Florida. The platform they developed combines the imaging capabilities of the Philips MRI scanner with the processing power of the Stampede supercomputer – one of the fastest in the world – using the TACC-developed Agave API Platform infrastructure to facilitate communication, data transfer, and job control between the two.

An API, or Application Program Interface, is a set of protocols and tools that specify how software components should interact. Agave manages the execution of the computing jobs and handles the flow of data from site to site. It has been used for a range of problems, from plant genomics to molecular simulations, and allows researchers to access cyberinfrastructure resources like Stampede via the web. “The Agave Platform brings the power of high-performance computing into the clinic,” said William (Joe) Allen, TACC. “This gives radiologists and other clinical staff the means to provide real-time quality control, precision medicine, and overall better care to the patient.”

As a demo, UTHSC staff performed MRI scans on a patient with a cartilage disorder to assess the state of the disease. Data from the MRI was passed through a proxy server to Stampede where it ran the GRAPE (GRAphical Pipelines Environment) analysis tool. This tool characterizes the scanned tissue and returns pertinent information that can be used to do adaptive scanning – essentially telling a clinician to look more closely at a region of interest, thus accelerating the discovery of pathologies.

Computer systems and software involved in real-time MRI analysis platform. Red numbers 1-4 indicate the sequence of data and signal flow between systems.

Computer systems and software involved in real-time MRI analysis platform. Red numbers 1-4 indicate the sequence of data and signal flow between systems.

The researchers demonstrated the system’s effectiveness using a T1 mapping process, which converts raw data to useful imagery. The transformation involves computationally-intensive data analyses and is therefore a reasonable demonstration of a typical workflow for real-time, quantitative MRI. A full circuit, from MRI scan to supercomputer and back, took ~5 minutes to complete and was accomplished without any additional inputs or interventions. The system is designed to alert the scanner operator to redo a corrupted scan if the patient moves, or initiate additional scans as needed, while adding only minimal time to the overall scanning process.

Refaat Gabr, an assistant professor of Diagnostic and Interventional Imaging at UTHSC said: “By integrating the computational power of TACC, we plan to build a completely adaptive scan environment to study multiple sclerosis and other diseases.”

Ponnada Narayana, Gabr’s, University of Texas Medical School at Houston, elaborated. “Another potential of this technology is the extraction of quantitative, information-based texture analysis of MRI,” he said. “There are a few thousand textures that can be quantified on MRI. These textures can be combined using appropriate mathematical models for radiomics. Combining radiomics with genetic profiles, referred to as radiogenomics, has the potential to predict outcomes in a number diseases, including cancer, and is a cornerstone of precision medicine.”

According to Allen, “science as a service” platforms like Agave will enable doctors to capture many kinds of biomedical data in real time and turn them into actionable insights. “Here, we demonstrated this is possible for MRI. But this same idea could be extended to virtually any medical device that gathers patient data,” he said. “In a world of big health data and an almost limitless capacity to compute, there is little reason not to leverage high-performance computing resources in the clinic.” https://www.tacc.utexas.edu/-/real-time-mri-analysis-powered-by-supercomputers